58,000 USG 250 PSI Bullet


Description

2004 Universal Industries 58,000 USG (7,740 ft³) propane/butane storage bullet, ASME VIII Div. 1, 250 psi MAWP at 125°F. Its 2014 internal inspection found no corrosion or weld indications. Currently connected in Flagstaff County, AB.

General Info
Year Built:
2004
Condition Rating:
C — Used, Degraded
Condition Details:
Last inspected July 2014 (external + internal VI, UT, 100% WFMPI): fit for service, no corrosion or weld indications. Currently connected; present condition not verified since 2014.
Connection Status:
Connected
Last Inspection:
Jul 23, 2014
Units Available:
1
Vessel Info
Manufacturer:
Universal Industries
Service Type:
Sweet
Capacity:
58,000 USG
Diameter:
126"
Vessel Length:
88'
Vessel Dimensions:
126" X 88'
Position:
Horizontal
Pressure:
250 PSI
MDMT:
-40 °F
Insulated:
No
Skidded:
No
Housed:
No
Serial #:
03-10-90
CRN #:
R5692.23
Tag #:
11444
Notes:

Full document package available on request: manufacturer's U-1A/U-4 data reports and the July 2014 external and internal inspection reports.

Construction

  • ASME Section VIII, Division 1, U-stamped. Alberta registration A0509920.
  • Shell: SA-516-70, 0.875" nominal thickness, 10' 4.25" ID, 9 courses, full radiography on long seams.
  • Heads: 2:1 elliptical, SA-516-70, 0.7966" minimum thickness.
  • Design temperature 125°F, hydrotested at 325 psi. Impact-tested components are rated to -50°F.
  • Saddle supports welded at each end. 24" RFWN manway.

Nozzles (all 300# RF unless noted)

  • Pressure relief: 2 x 4"
  • Fill: 4"
  • Liquid out: 2 x 3"
  • Vapour with internal riser: 2 x 2"
  • Inlet fuel gas, recycle and spare (blinded): 2" each
  • Sight gauges: 2 x 2"
  • Float gauge 2-1/2", roto gauge 2", plus 3/4" pressure/level gauge and thermowell connections on the heads

Over-pressure protection

  • Two manifolds with four Rego relief valves each, 2-1/2" inlet, set at 250 psi. All eight valves were purchased new in May 2013.

Inspection history (July 2014)

  • External: no concerns. Supports, foundation, piping, valves, coating, ladder and platform were all acceptable. UT found no issues.
  • Internal: heads, shell, nozzles and all welds in good condition with no corrosion. 100% wet fluorescent magnetic particle inspection of all seams, nozzles and attachment welds found no indications. Light scaling was noted at the bottom of the shell.
  • The inspector rated it fit for service and eligible for a Grade 2 (10-year) internal inspection interval under AB-506. The next internal inspection was recommended for 2024, so a buyer should plan on a re-inspection and PSV service before putting it back into service.
Financial Info
Availability Status
Available
Location
Nearest Town / City
Flagstaff County
Province
AB
Country
Canada