2.5" 90 ft² Double Pipe Exchanger
bookmark_border WatchNew 2013 Heat Exchanger Design, Inc. double pipe exchanger, 2.5 in x 20 ft, 90 ft², ASME U-stamped, MAWP 1,110 psi at 352 °F shell / 1,440 psi at 302 °F tube, Alberta CRN W2682.2.
New 2013 double pipe heat exchanger by Heat Exchanger Design, Inc., built to ASME Section VIII Div. 1 (U stamp) and rated 1,110 psi at 352 °F shell side and 1,440 psi at 302 °F tube side. Its 2.5 in x 20 ft, 90 ft² layout suits high-pressure natural gas heating or cooling on a small stream, and both sides are rated for full vacuum. It is registered in Alberta under CRN W2682.2 and rated Condition A (new).
Key Specs
- Type: double pipe heat exchanger
- Manufacturer: Heat Exchanger Design, Inc. (USA)
- Model: SH4K1-20-00-24UV-2B3C
- Size: 2.5 in diameter x 20 ft
- Heat transfer surface: 90 ft²
- Material: SA-106-B/C
- Year built: 2013
- MAWP shell side: 1,110 psi at 352 °F (7,653 kPa at 178 °C)
- MAWP tube side: 1,440 psi at 302 °F (9,930 kPa at 150 °C)
- External pressure: full vacuum, shell and tube side
- MDMT: -20 °F (-29 °C) at 1,110 psi shell / 1,440 psi tube
- Hydrotest: 1,443 psi shell / 1,872 psi tube
- Nameplate service: natural gas heater (sweet)
Nameplate / Registration
- Code stamp: ASME U, W, RT-4
- National Board No.: 3532
- Serial: 4474
- CRN: W2682.2 (ABSA directory: Heat Exchanger Design, Inc., heat exchanger, drawing 4474 sheets 1-8, registered 2013)
Condition
- Rated A (new, unpackaged)
- Photographed crated with nameplate intact
- Connection status: disconnected
What's Included
- One double pipe heat exchanger as described
Photos & Documents
- Gallery includes the exchanger nameplate (imperial and metric ratings) and crated views
- Gallery also shows other crated equipment; confirm scope with IronHub
- Drawings, data report and P&ID are not posted; request them through IronHub
Verification Recommendations
- Request the manufacturer's data report (U-1A) and drawing 4474, sheets 1-8
- Confirm model, material and surface area against the drawing
- Confirm registration for the destination province if outside Alberta
- Inspect nozzles and flange faces after storage