96" x 20' 200 bbl 15 PSI Flare Knockout Internally Coated
bookmark_border WatchSupporting Documents (1)
library_books8' OD x 20' S/S horizontal above-ground flare knockout (200 bbl) by Tornado Technologies, 2005, 14.7 psig MAWP (non-registered), internally coated (Devoe 253), 10" 150# inlet/outlet, in an insulated building on a skid with containment pan and transfer pump. Disconnected, Stettler, AB.
96" (8' OD) x 20'-0" S/S, 200 bbl Horizontal Flare Knockout – Tornado, 2005, Internally Coated, Skidded & Housed
VESSEL (per Tornado general arrangement drawing and nameplate)
- Manufacturer: Tornado Technologies Inc. (Stettler, AB); model 8 x 20 AGKO (above-ground knockout); serial no. 5-8033; built 2005
- Size: 8'-0" OD x 20'-0" S/S, horizontal; nominal capacity 200 bbl
- Nameplate MAWP: 14.7 psig (drawing design pressure 50 psig, design temperature 100°F; hydrotested to 75 psig)
- Non-registered vessel (≤15 psig); drawing shows CRN N/A
- Shell: 3/8" SA-516-70; heads: 3/8" 2:1 SE SA-516-70; corrosion allowance 1/8"; no PWHT, no radiography
- Internal coating: internally blasted SSPC-SP10 and coated with Devoe 253 (vessel decal: 10–12 mils, applied Aug 2005; drawing spec 10–18 mils); exterior sandblasted SSPC-SP6 with gloss finish
NOZZLES (per drawing bill of materials, 150# RFWN unless noted)
- N1 inlet: 10" with inlet deflector
- N2 outlet: 10" with outlet deflector
- N3/N4 float bridle: 2" Sch 80
- N5 vent/relief: 3"
- N6 truck-out: 3"; N8 pump-out: 3"
- N7 auto-purge gas: 2" (blind tapped 3/8")
- N9/N10 level transmitter: 2" Sch 80
- M1 manway: 20" with blind
- Sight glass, level-check and bridle drain couplings; float bridle with red-line sight glass, isolation valves and electric level switch
PACKAGE (per skid & building drawing and photos)
- Skid: 12" W-beam main skid beams, 38'-0" long, with checker-plate floor
- Insulated panel building over the vessel with full-access double doors
- Containment pan: 35'-0" L x 10'-6" W x 42" high
- Two 24,000 BTU/hr natural-gas catalytic flameless heaters (120 VAC start)
- 3" pressure/vacuum (PVRV) vent assembly set at 10 psi with bird screen and auto-purge valve assembly
- Transfer pump: Eagle centrifugal pump with 3 HP TECO-Westinghouse TEXP explosion-proof motor (230/460 V, 3-phase, Class I Div 1 rated)
- Estimated weights (drawing): knockout 9,175 lb; skid 8,270 lb; total 17,445 lb
CONDITION & STATUS
- Used, good condition (PASC B); disconnected; located near Stettler, AB
- 29 photos including nameplate, coating decal, pump/motor plates and vessel interior
- Documents available: general arrangement, bill of materials, skid & building detail, meter-run piping detail
BUYER NOTES
- Original drawings also show a 2" meter run with chart recorder; confirm its presence at inspection.
- Inspect the internal coating before return to service.