Waste Water Management System (Induced Gas Flotation - IGF)
Listing ID:
IH-38549
Notes:
Design Pressure: Liquid Full + 1 psi
Operating Pressure: Atmospheric
Design Temperature: 149F (65C)
Operating Temperature: 15- 30°C
Wastewater Flow Rate: 20,000 BWPD
Oil Specific Gravity: 0.85 (assumed)
Water Specific Gravity: 1.03 (assumed)
Influent to treatment: <2,000 PPM
Effluent from treatment: <29 PPM*
* Note: Chemical additives (by others) may be required to achieve effluent.